5000W 5KW Hybrid Solar Inverter Off Grid 48V DC to 110V 120V 220V AC Output with 80A MPPT Solar Charger Max 500V PV HSI5000U
SPECIFICATIONS
Brand Name: TINGEN
Certification: CE
High-concerned chemical: None
Is Smart Device: Yes
Origin: Mainland China
Output Frequency: 50HZ, 60HZ
Size: 426*322*126
Weight: 12KG
is_customized: Yes
5000W 5KW Hybrid Solar Inverter Off Grid 48V DC to 110V 120V 220V AC Output with 80A MPPT Solar Charger Max 500V PV HSI5000U HSI5500

HSI 5000U is a new solar storage inverter, which integrates solar energy storage & mains charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard. The solar charge module adopts the latest optimized MPPT tracking technology, which can quickly track the maximum power point of the PV array in any environment to obtain the maximum energy of the solar panel in real time with wide voltage range of MPPT.

Features:
Rated power 5000W, Peak power 11000VA 48VDC
MPPT PV ranges120V~450V dc, max. 500V Voc input
Maximum PV ChargeCurrent 80A
American standard110V/120V AC output
Two output modes: mains bypass and inverter output; uninterrupted power supply.
Power saving mode available to reduce no-load loss.
WIFI remote monitoring (optional)
Lithium battery/Lead-acid battery
【4 modes can be choose when charging battery】
Utility first: Utility will charge battery as first priority source, then Solar Power.
Solar first: Solar will charge battery as first priority source, then Utility Power.
Solar and Utility(default): Solar Power and Utility power will charge battery at the same time.
Only Solar: Solar Energy as the only source charge battery.

【3 output modes can be choose】
Utility first (default):Utility will provide power to theloads as first priority, Then Solar Power, battery Power
Solar first: Solar energy provides power to the loads as first priority. If solar energy is not sufficient to power all connected loads, utility will supply power to the loads at the same time,then battery power.
SBU Priority: Solar energy provides power tothe loads as first priority. If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time.




Model |
HSI 5000U |
AC mode | |
Rated input voltage |
110/120Vac |
Input voltage range |
(90Vac~140Vac)±2% |
Frequency |
50/60Hz(auto-detect) |
Overload/short-circuit protection |
Breaker |
Efficiency |
>95% |
Conversion time |
10ms(Typical value) |
Bypass and inverting | |
Maximum bypass overload current |
63A |
Inverter mode | |
Output voltage waveform |
Pure sine wave |
Rated output power |
5000VA/5000W |
Power factor |
1 |
Rated output voltage (Vac) |
120Vac(100/105/110/120Vac Settable) |
Efficiency |
>90% |
Peak power |
11000VA |
Rated battery input voltage |
48V (minimum start voltage 44V) |
Battery voltage range |
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage |
Self-consumption power |
Non-energy saving mode ≤50W, Energy saving mode <25W |
AC charge | |
Battery type |
Lead acid or lithium battery |
Maximum charge current |
40A |
Charge voltage range |
40–60Vdc |
Solar charge | |
Maximum PV open circuit voltage |
500Vdc |
PV operation voltage range |
120-500Vdc |
MPPT voltage range |
120-450Vdc |
Battery voltage range |
40-60Vdc |
Maximum input power |
6000W |
Charge current range of solar energy (settable) |
0~80A |
Certified specifications | |
Certification |
CE(IEC62109-1)/CETL(UL1741 C22.2 NO.107.1)/FCC/SAA |
EMC authentication grade |
EN61000 |
Operation temperature range |
-10°C to 55°C |
Storage temperature range |
-25°C ~ 60°C |
Humidity range |
5% to 95% (three-proof paint protection) |
Noise |
≤60dB |
Thermal dissipation |
Forced cooling with adjustable air speed |
Communication interface |
USB/RS485 (WiFi/GPRS)/Dry contact |
Dimension |
426*322*126mm |
Weight |
11.6kg |